Description |
Specification |
EchoSafe, an ultrasonic level transmitter designed for hazardous applications, where an agency certified sensor is needed. A 2-wire (loop-powered) ultrasonic level transmitter that provides non-contact level measurement up to 10 m (32.8') in hazardous (classified) bulk storage, day tank, waste treatment and sump applications, and is well suited for challenging corrosive, slurry or waste media. |
|
Range:
|
8" to 32.8' (20cm to 10m)
|
Signal output:
|
4-20 mA, two-wire
|
Enclosure rating:
|
NEMA 4
|
Process mount:
|
2" NPT
|
|
|
|
Description |
Specification |
CSA approved intrinsically safe for use in hazardous zones, the non-contact level transmitter is ideal for atmospheric bulk storage, day tank and waste sump applications up to 18' (5.4m). Compact and rugged, the push button calibrated transmitter is reliable and easy to configure. Its hazardous level made simple. |
|
Range:
|
6" to 18' (15cm to 5.4m)
|
Signal output:
|
4-20 mA, two-wire
|
Enclosure rating:
|
IP65
|
Process mount:
|
2" NPT (2" G)
|
|
|
|
Description |
Specification |
Fluidweell is a CSA approved explosion proof for use in hazardous applications, the loop powered field meter displays engineering units connected in series with one 4-20 mA transmitter. The meter is typically selected for use with an explosion proof transmitter within a hazardous area. The windowed field enclosure is wall mounted for convenient viewing. |
|
Display type:
|
LCD, 5 1/2 digit
|
Sensor input:
|
(1) 4-20 mA input
|
Contact type:
|
None
|
Enclosure mount:
|
Field
|
|
|
|
Description |
Specification |
DataLoop is offered in intrinsically safe and general purpose configurations, the loop powered panel meter displays engineering units connected in series with one 4-20 mA transmitter. Select the LI25-2001 meter for hazardous applications with an intrinsically safe level transmitter. Select the LI25-1001 meter for general purpose applications. For field mount installations, order the single or two meter NEMA box. |
|
Display type:
|
LCD, 5 digit
|
Sensor input:
|
(1) 4-20 mA input
|
Contact type:
|
None
|
Enclosure mount:
|
1/8 DIN, panel mount
|
|
|
|
Description |
Specification |
EchoSpan is the advanced non-contact level measurement solution for atmospheric storage tanks up to 32' (10m) including bulk storage, day tank and waste sump applications. Calibration is fast and simple with our scrolling single layer menu, three button interface and 6-segment LCD display. Its full featured level made simple. |
|
Range:
|
4" to 32.8' (10cm to 10m)
|
Signal output:
|
4-20 mA, two-wire
|
Enclosure rating:
|
IP65
|
Process mount:
|
2" NPT (2" G)
|
|
|
|
Description |
Specification |
The EchoSonic II general purpose two-wire ultrasonic transmitter provides non-contact level measurement up to 32.8' (10 m). Well suited for challenging ultrapure, corrosive, slurry or waste liquids, this second-generation transmitter is often selected for atmospheric bulk storage, day tank, waste sump, process vessel, IBC tote, 55-gallon drum and waste sump applications |
|
Range:
|
4" to 32.8' (10cm to 10m)
|
Signal output:
|
4-20 mA, two-wire
|
Enclosure rating:
|
Type 6P
|
Process mount:
|
1" / 2" NPT (1" / 2" G)
|
|
|
|
Description |
Specification |
WebCal software makes level measurement, switch and control configuration fast and easy. Take control of your level process with WebCal's intuitive interface, pre-programmed menus, tank set point graphics and custom wiring diagrams. To configure your WebCal enabled sensor, simply download your free copy of WebCal, create or open a saved configuration file, and click Write to Unit. Its that simple. |
|
OS required:
|
Windows® XP & 2000
|
HD space required:
|
10 MB
|
RAM required:
|
256 MB
|
Ports required:
|
(1) USB® 2.0
|
|
|
|
Description |
Specification |
Echotouch provides non-contact level measurement of atmospheric bulk storage tanks up to 24.5' (7.4m) with an integral relay for alarm or automatic fill or empty control. Compact and rugged, the push button calibrated transmitter is reliable and easy to configure. Its level measurement and control made simple. |
|
Range:
|
6" to 24.5' (15cm to 7.4m)
|
Signal output:
|
4-20 mA, three-wire
|
Enclosure rating:
|
IP65
|
Process mount:
|
2" NPT (2" G)
|
|
|
|
Description |
Specification |
The general purpose two-wire, float transmitter provides contact level measurement up to 8' or 2.4m, and is ideally suited for relatively clean water, light weight oil or diluted corrosive liquids. The transmitter is typically selected for hight temperature and/or pressure process tank applications. Media examples include boiler water and cooking oil. |
|
Range:
|
5" to 6' (12.7cm to 1.8m)
|
Signal output:
|
4-20 mA, two-wire
|
Enclosure rating:
|
IP65 / NEMA 4X
|
Process mount:
|
2" NPT (2" G)
|
|
|
|
Description |
Specification |
The general purpose two-wire pressure transmitter is offered in two termination packages and provides contact level measurement up to 69' or 21.1m of water column. Select the -S_01 for cable termination or the -S_11 for conduit termination with an integral junction box. The transmitter is best applied with clean liquid or gas media including water, oil and air. Application examples include irrigation equipment, pumping systems and compressors. |
|
Range:
|
0 psi (0 bar) - 30 psi (2 bar)
|
Signal output:
|
4-20 mA, two-wire
|
Enclosure rating:
|
IP65
|
Cable length:
|
9' (3 m)
|
|
|
|
Description |
Specification |
The general purpose two-wire pressure transmitter is offered in two configurations for different liquid types and provides contact level measurement up to 46' or 14m of water column. Select the LD31 for clean or relatively clean water, light weight oils and diluted chemical media. Application examples include ground water, ponds and wells. Select the LD32 for dirty, sludge or slurry media. Application examples include sewer or storm pump lift stations, storage and treatment with surface foam or debris where ultrasonic cannot be applied. |
|
Range:
|
0 psi (0 bar) - 20 psi (1.38 bar)
|
Signal output:
|
4-20 mA, two-wire
|
Enclosure rating:
|
IP67
|
Cable length:
|
40' (12.2 m) or 60' (18.3 m)
|
|
|
|
Description |
Specification |
DataView is a general purpose meter displays engineering units with one 4-20 mA or 0-10 VDC transmitter input channel and is offered in three configurations with optional 2 or 4 relays, 4 or 8 set points and an isolated 4-20 mA repeater. Each relay can be configured on a single set point or latched on two set points for automatic fill or empty control including duplexing. For field mount installations, order the single or two meter NEMA box. |
|
Display type:
|
LED, 6 digit
|
Sensor input:
|
(1) 4-20 mA input
|
Contact type:
|
(4) 3A SPDT relays
|
Enclosure mount:
|
1/8 DIN, panel mount
|
|
|
|
Description |
Specification |
A compact all-in-one solution with controller, graphics and removable mass storage for industrial applications starting below the cost of a micro PLC plus operator interface. The commander series is small enough to fit in the palm of your hand, and includes a graphical operator interface and Removable Mass Data Storage. |
|
Display:
|
Backlit LCD
|
Input channel:
|
(1) 4-20 mA
|
Contact type:
|
(6) mechanical contact relays
|
Enclosure mount:
|
35 mm DIN rail
|
|
|