Description |
Specification |
The general purpose, ultrasonic sensor provides non-contact level detection up to 98.4" (2.5m) with 4 SPST 60 VA 1A relays and a two-wire 4-20 mA level measurement output. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. EchoPod is broadly selected for day tanks, sumps, IBC totes, lift stations and mini-bulk storage applications. |
|
Range:
|
4" to 8.2' (2.5m)
|
Signal output:
|
4-20 mA, two-wire
|
Contact type:
|
(4) SPST relays 1A
|
Enclosure rating:
|
Type 6P
|
Process mount:
|
1" NPT (1" G)
|
|
|
|
Description |
Specification |
The general purpose, ultrasonic sensor provides non-contact level detection up to 49.2" (1.25m) with 4 SPST 60 VA 1A relays and a two-wire 4-20 mA level measurement output. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. EchoPod is broadly selected for small atmospheric day tank, skid or process vessel, lift station, IBC, drum and sump applications. |
|
Range:
|
2" to 49.2" (1.25m)
|
Signal output:
|
4-20 mA, two-wire
|
|
Contact type:
|
(4) SPST relays 1A
|
Enclosure rating:
|
Type 6P
|
Process mount:
|
1" NPT (1" G)
|
|
|
|
Description |
Specification |
The general purpose, ultrasonic sensor provides non-contact level detection up to 49.2" (1.25m) with 4 SPST 60 VA 1A relays. The DS14 directly replaces contact switches connected to a PLC with 1-4 discrete points for easy design conversion or field retrofit. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DS14 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel, lift station and sump applications. To configure EchoPod, download our free WebCal software and purchase one USB interface tool. |
|
Range:
|
2" to 49.2" (1.25m)
|
Signal output:
|
None
|
Contact type:
|
(4) SPST relays 1A
|
Enclosure rating:
|
Type 6P
|
Process mount:
|
1" NPT (1" G)
|
|
|
|
Description |
Specification |
The general purpose, DX10 ultrasonic sensor provides non-contact level measurement up to 49.2" (1.25m) with a 0-5 VDC, 0-10 VDC or 976-2000 Hz. frequency output. Select the voltage output to directly replace a contact measurement sensor connected to a PLC analog input. Select the frequency output to replace a contact measurement sensor or switch assembly, and eliminate the cost of an analog input card by connecting the DX10 to a PLC discrete input. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DX10 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel and sump applications. To configure EchoPod, download our free WebCal software and purchase one USB interface tool. |
|
Range:
|
2" to 49.2" (1.25m)
|
Signal output:
|
0-5 V, 0-10 V, 976-2000 Hz
|
Contact type:
|
None
|
Enclosure rating:
|
Type 6P
|
Process mount:
|
1" NPT (1" G)
|
|
|
|
Description |
Specification |
The general purpose, DL10 ultrasonic sensor provides non-contact level measurement up to 49.2" (1.25m) with a 4-20 mA output. The DL10 directly replaces contact measurement sensors connected to a PLC analog input card for easy design conversion or field retrofit. The two-wire, 4-20 mA output is ideal for longer signal distances up to 1000'. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DL10 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel and sump applications. To configure EchoPod, download our free WebCal software and purchase one USB interface tool. |
|
Range:
|
2" to 49.2" (1.25m)
|
Signal output:
|
4-20 mA, two-wire
|
Contact type:
|
None
|
Enclosure rating:
|
Type 6P
|
Process mount:
|
1" NPT (1" G)
|
|
|
|
Description |
Specification |
WebCal software makes level measurement, switch and control configuration fast and easy. Take control of your level process with WebCal's intuitive interface, pre-programmed menus, tank set point graphics and custom wiring diagrams. To configure your WebCal enabled sensor, simply download your free copy of WebCal, create or open a saved configuration file, and click Write to Unit. Its that simple. |
|
OS required:
|
Windows® XP & 2000
|
HD space required:
|
10 MB
|
RAM required:
|
256 MB
|
Ports required:
|
(1) USB® 2.0
|
|
|