Designed to provide the rugged portability needed in the field with the accuracy demanded in the laboratory, the EPA accepted DRT-15CE has become a must have for anyone monitoring turbidity on the go. The integral carrying case holds everything needed for field operation. With resolution of 0.01 NTU and an extended range to 1,000 NTU, the DRT-15CE is a perfect fit for both field and laboratory use.
Features
- Rugged portable carrying case
Ensures durability and convenience no matter where your laboratory happens to be
-
Completly self contained
Provides easy access to everything you need to take a measurement
-
Three user selectable ranges
Provides accuracy in a wide variety of applications from 0 to 1000 NTU
-
20 hour rechargeable battery
Always be ready to go with up to 20 hours of continuous operation when fully charged
-
Made in the USA
Optional Features
Specifications
Principal of operation |
Nephelometric -USEPA Method 180.1 |
Range |
0 - 10 NTU, 0 - 100 NTU, 0 - 1000 NTU |
Accuracy |
0-10 NTU ± 1% of full scale |
|
0-100 NTU, ±5% of full scale |
|
0-1000 NTU, ±10% of full scale |
Resolution |
0.1% of selected range |
Response time |
Immediate |
Sample size |
25 ml (16 ml minimum) |
Operating temperature |
0° to 50°C (32° to 122°F) |
Battery |
6V gel-cell rechargeable with 20 hours of continuous use when fully charged |
Recharge time |
8 hours to full charge |
Dimensions |
11 x 8 x 5 inches (28 x 20 x 14 cm) |
Weight |
5 lbs. (2.27 kg) |
Safety rating |
UL, CSA |
Literature and Specifications
Operator's Manual
Chlorine Pocket Photometer Instruments and Accessories
Instruments
Model |
Description |
19057 |
DRT-15CE Portable Turbidimeter, 0 - 1000 NTU, (white light 120V) includes battery charger, sample cuvette with light shield cap, 0.02 NTU reference standard, recorder output plug and instruction manual. |
19058 |
DRT-15CE Portable Turbidimeter, 0 - 1000 NTU, (white light, 240V) includes battery charger, sample cuvette with light shield cap, 0.02 NTU reference standard, recorder output plug and instruction manual. |
Accessories
Model |
Description |
19045 |
Auto adapter 12 volt |
19975 |
Pour through assembly (includes the assembly, locking ring, 24" of drain tubing, cuvettes and instructions). |
19981 |
Cuvette stand (for storing empty cuvettes as well as calibration standards; holds up to 11 cuvettes) |
20115 |
Adapter kit, 16 mm factory installed |
21084 |
Source lamp assembly, 2 pack |
39071 |
ProCal Primary calibration kit (0.02, 10, 100, 1000 NTU) |
39824 |
ProCal Primary Calibration Standard - 100 NTU |
39825 |
ProCal Primary Calibration Standard - 10 NTU |
50040 |
Formazin Stock Solution Kit - Primary Calibration - each kit contains: 32 onces of 4000 NTU Formazin, one gallon 0.02 NTU Reference Standard, four cuvettes with indexing light shields, three pipettes and instruction manual |
50048 |
Cuvette 16mm 3 pack with light shields (requires adapter, catalog #20115) |
50051 |
Cuvette 28 x 70 mm 3/pk (replaces 28 x 93 mm) use for grab sample. Includes threaded light shield caps. |
50052 |
Cuvette 28 x 70 mm 10/pk (replaces 28 x 93 mm) use for grab sample. Includes threaded light shield caps. |
60013 |
ProCal calibration standard 0.02 NTU (complete with indexing light shield) |
70008 |
Rechargable battery |
|