Designed to provide the accuracy demanded by todays scientist, the Micro100 Laboratory Turbidimeter is ready to meet the challenge. Features like the Auto Alert Calibration Prompt and the Quick Connection Lamp Module, allow for simple calibration and low maintenance. With a resolution of 0.01 NTU at low turbidity readings and an extended range to 1,000 NTU, the Micro100 is an ideal and affordable tool for research as well as routine analytical measurements.
Features
-
Auto ranging 0 - 1000 NTU
Instrument senses turbidity level of sample and automatically adjusts to the appropriate measurement
-
Auto alert calibration prompt
Automatically prompts the operator when calibration of the instrument is needed
-
Simple calibration procedures
Calibration initiated with the push of a button ensures accurate readings
-
RS-232 output
Date, time, and NTU reading can be captured with a serial printer or data recorder
-
Made in the USA
Optional Features
- Infrared light source (Micro100 IR)
Meets international standard ISO 7027 for turbidity measurement
-
Pour-through assembly
Save time by pouring your grab sample through the measurement chamber
-
ProCal calibration standards
Quick and easy calibration across all ranges without the need to mix Formazin
Specifications
Principal of operation |
Nephelometric non-ratio |
Range |
Auto ranging from 0 - 1000 NTU |
Accuracy |
± 2% of reading plus 0.01 NTU |
Resolution |
0.01 NTU (0 - 9.99 NTU) |
|
0.1 NTU (10 - 99.9 NTU) |
|
1 NTU (100 - 1000 NTU) |
Response time |
less than 6 seconds |
Sample size |
30 ml (27ml minimum) |
Light source |
Quick connect Tungsten Filament or Infrared Operating |
Temperature |
32° - 122°F (0° - 50°C) |
Outputs |
RS-232 serial port |
Dimensions |
10.75 x 10 x 3.75 inches (27.3 x 25.4 x 9.5 cm) |
Weight |
2.9 lbs. (1.32 kg) |
Safety rating |
UL, CSA, CE |
Literature and Specifications
Operator's Manual
Chlorine Pocket Photometer Instruments and Accessories
Instruments
Model |
Description |
19950 |
Micro100 WL Laboratory Turbidimeter, 0 - 1000 NTU, Universal Power 100-240V 50-60 Hz Includes a complete set of calibration standards (0.02, 10 and 1000 NTU), two measuring cuvettes with light shield cap, operator's manual and a universal power adapter that operates at any voltage between 100-240VAC. |
19952 |
Micro100 IR Laboratory Turbidimeter, 0 - 1000 NTU, Universal Power 100-240V 50-60 Hz Includes a complete set of calibration standards (0.02, 10 and 1000 NTU), two measuring cuvettes with light shield cap, operator's manual and a universal power adapter that operates at any voltage between 100-240VAC. |
20001 |
Micro100 WL Laboratory Turbidimeter, 0 - 1000 NTU, 120V 60 Hz Includes a complete set of calibration standards (0.02, 10 and 1000 NTU), two measuring cuvettes with light shield cap, operator's manual and 120VAC power adapter. |
Accessories
Model |
Description |
19785 |
Cable RS-232, Micro100 - Micro1000 |
19786 |
Batteries, lithium - pkg of 2 |
19889 |
Flow through assembly (complete kit) |
19972 |
Replacement lamp module (white light) |
19975 |
Pour through assembly (includes the assembly, locking ring, 24" of drain tubing, cuvettes and instructions). |
19981 |
Cuvette stand (for storing empty cuvettes as well as calibration standards; holds up to 11 cuvettes) |
22423S |
Replacement lamp module (Infrared) |
22580 |
Universal power supply 100 - 240 volts |
39825 |
ProCal Primary Calibration Standard - 10 NTU |
39957 |
ProCal Primary Calibration Kit, Full Range, .02, 10, and 1000 NTU (for MicroTOL 2, 4 and Micro100) |
50040 |
Formazin Stock Solution Kit - Primary Calibration - each kit contains: 32 onces of 4000 NTU Formazin, one gallon 0.02 NTU Reference Standard, four cuvettes with indexing light shields, three pipettes and instruction manual |
50051 |
Cuvette 28 x 70 mm 3/pk (replaces 28 x 93 mm) use for grab sample. Includes threaded light shield caps. |
50052 |
Cuvette 28 x 70 mm 10/pk (replaces 28 x 93 mm) use for grab sample. Includes threaded light shield caps. |
70050 |
Wall power supply/charger 120 volts |
|