Have a hot water, high volume application that requires a high degree of accuracy with low maintenance features?
Then Carlon has a family of meters for you. Our hot water turbine meters are available in sizes from 3/4" to 6", with larger sizes available upon request.
Carlon offers temperature ratings for its hot water turbine meters at 248ºF. These turbine meters provide +/- 2% accuracy at flow rates from 1 GPM all the way up to 2,500 GPM.
Our turbine meters are all available in totalizing and electric contact configurations so that you can run your other process equipment (Carlon valves, timers, controllers and chemical pumps) directly from our turbine meter.
Offering These Advantages
-
Hot Water Meters for temperatures up to 248ºF in sizes from 3/4 "to 6"
-
All available in both Totalizing and Electric Contacting Models for the control of water treatment equipment, such as chemical feed pumps, timers, valves, etc.
-
Optional Car-Logger units available
-
Consult factory for larger size meters 8" to 20".
-
On 2" larger sizes, register can rotate 340 degrees for ease of reading meter after installation
Water Meter Connections
Product Details
Main Case: |
Epoxy Coated Cast Iron |
Operating Pressure Range: |
15 to 232 p.s.i. |
Temperature Range(s) 3/4" thru 1-1/2" sizes: |
25-248ºF |
2" and larger sizes: |
25-248ºF Hot Water Series |
Accuracy: |
± 2% of Flow Rate |
Registration: |
U.S. Gallons |
Electric Contacting Models: |
Maximum Switching Voltage 48 volts AC/DC Maximum Current .2 amps, 3 watts |
Specifications for Hot Water Turbines
Model
|
H075
|
H100
|
H150
|
H200
|
H300
|
H400
|
H600
|
Size |
3/4"
|
1"
|
1 1/2"
|
2"
|
3"
|
4"
|
6"
|
Flow Rate
in GPM |
1-20
|
2-50
|
3-85
|
2-132
|
5-352
|
8-528
|
20-1320
|
Gallon/Contact Settings
on EC Models
|
1/10/100
|
1/10/100
|
10/100
|
10/100
|
100/1000
|
100/1000
|
100/1000 |
Head Loss at PSI
Continuous Flow GPM
|
2
10
|
2
25
|
2
42
|
2
153
|
2
330
|
1
395
|
1
750
|
Dimensions – Inches:
|
Flanges
|
-
|
-
|
-
|
6 1/2"
|
8"
|
8 3/4"
|
11 1/4"
|
Bolt Holes
|
-
|
-
|
-
|
4
|
4
|
8
|
8
|
Bolt Hole-Dia.
|
-
|
-
|
-
|
5/8"
|
5/8"
|
5/8"
|
3/4"
|
Bolt Circle-Dia. |
-
|
-
|
-
|
4 3/4"
|
6"
|
7 1/2"
|
9 1/2"
|
Bore Diameter-
Continuous
|
-
|
-
|
-
|
2"
|
3"
|
4"
|
6"
|
Length
|
7 1/2"
|
10 1/4"
|
11 7/8"
|
7 7/8"
|
8 7/8"
|
9 7/8"
|
11 7/8"
|
Overall Width
|
3 3/4"
|
4"
|
5 1/2"
|
6 1/2"
|
7 7/8"
|
8 5/8"
|
11 1/4"
|
Height
|
6"
|
7 1/4"
|
8 1/8"
|
12 1/4"
|
13"
|
13 1/2"
|
14 1/4"
|
Center Line
to Base
|
-
|
-
|
1"
|
3"
|
3 3/4"
|
4 1/2"
|
5 3/4"
|
Weight in Lbs.
|
4.5
|
7
|
11.5
|
32
|
39
|
46
|
72
|