Model |
Upstream NC 30-75 (1" ) |
PART NUMBER (115 Volt) |
R000005 |
PART NUMBER (240 Volt) |
R000037 |
Validation / Certification |
Engineered to meet the same standards as NSF/ANSI 55 Class A certified UV systems. Validated to achieve 40 mJ/cm2 at maximum specified flow rates and minimum specified UVT. Certified to AB 1953. |
UV Dose |
minimum dose of 40 mJ/cm2 - 4 Log (99.99%) or greater reduction of bacteria, cysts and most viruses. Please refer to dose charts. |
Minimum UV Transmittance |
75% |
Max Flow Rate |
28.5 US gpm (108 L/min) (6.47 m3/hr) |
Water Pressure |
0 psi (69 kPa) to 100 psi (690 kPa); units are tested to 240 psi (1.6 MPa) |
Dynamic Flow Restrictor |
Installed as standard |
Pressure Drop at 75% of nominal flow capacity |
10 psi (69 kPa) |
Multiplexed Flow Capacity |
Engineered for multiple systems in parallel, for flow rates up to 1 MGD (696 US gpm) (2629 L/min) (158 m3/hr) |
Redundancy |
Additional backup systems can be added cost effectively |
Solenoid Shut-Off Valve |
Automatic shut-off valve available as option on all models |
Inlet and Outlet Connections |
1" NPT |
Voltage |
Models available in either 115V or 240V configurations (please see different part numbers above) |
Protection from Power Fluctuations |
115V Models include power conditioner that meets UL 1449. External power conditioner recommended on 240V models |
Maximum Power Consumption |
200W |
Electrical Certification |
Intertek ETL (UL, ULC and CE equivalent) |
Lamps |
Low pressure, high output proprietary lamps contain up to 30 mg of mercury (Hg); rated for 9000 hours (1 year) of continuous use |
Maintenance |
Onboard 9000 hour lamp life with lamp hour countdown to end of life. Automatic self-cleaning device prevents quartz sleeve from fouling and requires no maintenance |
Electronic Ballast |
Auto power-regulated smart ballast is integrated with micro-processor control system; protected from power fluctuations |
Self-Cleaning |
Stainless Steel patented automatic wiper-blade system keeps quartz free from scaling or bio-film |
On-Board Micro-Processor and Monitor |
Patented dual smart UV sensors continuously monitor UV dose, lamp intensity (UVI) and water transmittance (UVT); three thermistors continuously monitor air temperature and water temperature; on board LCD displays system performance, lamp hours, data logged operating events, and self-diagnosis including when to change lamps and troubleshooting assistance for service issues; on board LEDs indicate system status: OK, caution or alarm conditions. |
4-20 mA Analog Output |
Not available on Upstream models. Refer to Hallett specification page. |
Dry Contacts |
Included as standard for applications that require remote alarming, auto-dialer integration, or similar. |
Wireless Remote Monitor |
Available as option: RF 2.4 GHz remote monitor with LCD displays system status; operates up to 150 feet (50 meters) away from the main system |
Remote Alarm Start / Stop |
Included as standard on all models. Allows units to be remotely started / stopped. |
Dimensions (H, W, D) |
39.8 x 7.5 x 9.3" (1010 x 190 x 236mm) |
Weight - Dry |
30 lbs / 13.6 kg |
Weight - Wet |
33 lbs / 14.9 kg |
Warranty |
1 year limited warranty on bulbs and sensor probes; 3 year limited warranty on electrical components and quartz sleeve; 5 year limited warranty for structural, hardware and mechanical components |
EPA FIFRA Certified |
EPA Est. No. 075213-CAN-001 |
Patents |
Patented in US 6,707,048, Canada 2,463,503, Australia 2002333084, Mexico 248805, Patents pending in Europe, Eurasia, Japan, UK |
Recommended Application or Source Water |
Drilled wells or pre-treated water |